Sign In | Join Free | My himfr.com
Home > Rubber Duckbill Check Valve >

EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance

Henan Lianghe Pipeline Equipment Co.,Ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance from wholesalers
     
    Buy cheap EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance from wholesalers
    • Buy cheap EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance from wholesalers
    • Buy cheap EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance from wholesalers
    • Buy cheap EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance from wholesalers

    EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance

    Ask Lasest Price
    Brand Name : Liang He
    Model Number : XH-41
    Certification : ISO 9001
    Price : $14.3-18.6 per set
    Payment Terms : T/T, D/A, D/P, Western Union, MoneyGram, L/C
    Supply Ability : 8000 piece per month
    Delivery Time : 3-7 day
    • Product Details
    • Company Profile

    EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance

    EPDM flange type DN100 duckbill rubber check valve for sewage discharge corrosion abrasion weather resistance


    Installation method

    1. Prepare for installation: Ensure that the installation environment meets the requirements, including checking the caliber of the flange, pressure level, material and the material of the rubber body of the duckbill valve to ensure that they are suitable for the installation environment. At the same time, consider factors such as temperature, humidity and medium of the installation environment.

    2. Check the pipe end face: Use tools and methods to check the pipe end face to ensure that the inclination deviation of the cut end face does not exceed 1% of the outer diameter of the pipe and does not exceed 3mm. This is to ensure the tightness and safety of the flange connection.

    3. Flange connection: Use the flange angle ruler to check the verticality of the flange to ensure that the flange and the pipe are connected concentrically, and the bolts can be freely penetrated. The flanges should be parallel, and the deviation should not be greater than 1.5/1000 of the outer diameter of the flange, and should not exceed 2mm. Use bolts of the same specification for connection, each bolt should not be installed with more than one washer, and the bolt should be flush with the nut when fastening to ensure that the connection is tight and seamless.

    4. Increase gasket: Add gasket when connecting the flanged duckbill valve to ensure that the gasket size is consistent with the flange sealing surface, and the surrounding size is neat. The flange shall not be buried in the ground, and the flange of the buried pipeline or the pipeline that does not pass through the ditch shall be provided with inspection wells.

    5. Precautions: Attention should be paid to avoid the phenomenon of pressure deviation during installation, so as to prevent the medium from leaking out of the pressure deviation and affecting the safety of the pipeline. At the same time, flange connections should avoid installation in floors, walls and casings.


    Functions

    1. Automatically open and close according to the water pressure difference, safe and reliable.
    2. The positive opening has low water resistance, low starting pressure, and the flow rate is automatically adjusted according to the water pressure.
    3. The reverse check has good sealing performance, no leakage, and prevents backflow. The greater the back pressure, the better the effect.
    4. Anti corrosion, anti-aging, strong adaptability, and long service life.


    Main connection size

    Model

    Pipe Nominal

    Diameter

    Length(mm)High(mm)

    Flange outside

    diameter(mm)

    XH4150-150-F50150100150
    XH4180-220-F80220140200
    XH41100-250-F100250200225
    XH41150-340-F150340265275
    XH41200-420-F200420325338
    XH41250-520-F250520425400
    XH41300-620-F300620525485
    XH41350-700-F350700625525
    XH41400-800-F400800725588
    XH41450-900-F450900825625
    XH41500-980-F500980925688
    XH41600-1120-F60011201025800
    XH41700-1180-F70011801125969
    XH41800-1350-F800135014001080
    XH41900-1500-F900150015251150
    XH411000-1600-F1000160017251350
    XH411200-1840-F1200184019501485

    EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance


    EPDM Flange Type DN100 Rubber Duckbill Check Valve For Sewage Discharge Corrosion Abrasion Weather Resistance


    FAQ


    Q: What is rubber material?

    A: EPDM, CR, NBR, etc. This depends on the work environment and media.


    Q: Is the flange galvanized?

    A: Yes, we have electronic galvanized and hot-dip galvanized flanges. We also have painted flanges.


    Q: Can I customize the logo?

    A: Yes, we can provide OEM and ODM services for you.


    Q: Can you provide drawings?

    A: Yes, we can provide you with the drawings of the duckbill check valve. Please contact us to obtain the drawings of the duckbill check valve.


    Q: What is the pressure of work?

    A: 1.0-2.5Mpa.